1. Environmental protection: no freon, no heat pollution, integrates deodorization, ventilation, ventilation and cooling.
2. The cooling effect is obvious: generally, the cooling effect can reach 4℃-12℃, and the cooling speed is fast.
3. Large coverage area: the coverage area of each air cooler is 80-300m², the air supply volume per hour is 18000--30000m³, and the air supply distance is long.
4. Less investment and high efficiency (80% investment in central air conditioning can be saved.)
5. The use site can not close the doors and windows to ensure air circulation and increase the oxygen content in the air.
Air volume:30000m³/h
Application area :300-250㎡/set
Power :3KW
Voltage:380V/220V/Customized
Frequency:50Hz/60Hz
Fan type: Axial Flow Fan
Water consumption:25-30Kg/h
Noise:80(dB)
Outlet dimension(L*W) :800*800mm
Dimension( L*W*H):1250*1250*1200mm
Model |
Air volume(m³/h) |
Power (KW) |
Voltage(V) |
Outlet dimension (mm) |
Application area (㎡) |
Dimension ( L*W*H) (mm) |
YNC-180 |
18000 |
1.1/1.5 |
380 |
670*670 |
80-120 |
1080*1080*950 |
YNC-220 |
22000 |
2.2 |
380 |
670*670 |
100-150 |
1180*1180*1160 |
YNC-300 |
30000 |
3.0 |
380 |
800*800 |
150-200 |
1300*1300*1180 |
1. Installation environment
When installing the air cooler, it needs to be installed in a relatively nearby place with relatively fresh air, such as the outer wall and the roof. Of course, it is not advisable to install it near the toilet and the kitchen.
2. Installation method
The installation should be based on the location, select the appropriate size, determine the construction and installation of the pipeline, whether the link between the brackets is guaranteed, whether the pipeline will be blocked by obstacles, and whether the pipeline and hanger can be installed need to be considered.
3. Installation of exhaust port
The operation of the air cooler is to achieve the purpose of ventilation and cooling by inhaling the outdoor air, cooling the near-evaporative cooling pad and continuously conveying it to the room, and convecting the hot air and turbid air in the room to achieve ventilation and cooling. Therefore, the exhaust port needs to be equipped with a certain scale. Quantity, inlet and outlet ports should be kept in a ratio of 1:1. If there are many heating devices in the workshop and there is no exhaust port, enough exhaust ports should be opened at a height of more than 3 meters, or other equipment should be used to extract indoor hot air. , in order to achieve the ideal ventilation and cooling effect.