3kw 380v industrial evaporative air cooler 30000m³/h

Short Description:

Working principle of air cooler: The physical principle of using water evaporation to absorb heat and reduce the temperature of the surrounding air. When the fan is limited, negative pressure is generated inside the fan, causing the stuffy air flow outside the fan to pass through a moist cooling pad. By utilizing the principle of evaporation and heat absorption, the air temperature is lowered. The air cooler has the function of cooling and humidifying.


Product Detail

Product Tags

Advantage

1. Environmental protection: no freon, no heat pollution, integrates deodorization, ventilation, ventilation and cooling.

2. The cooling effect is obvious: generally, the cooling effect can reach 4℃-12℃, and the cooling speed is fast.

3. Large coverage area: the coverage area of ​​each air cooler is 80-300m², the air supply volume per hour is 18000--30000m³, and the air supply distance is long.

4. Less investment and high efficiency (80% investment in central air conditioning can be saved.)

5. The use site can not close the doors and windows to ensure air circulation and increase the oxygen content in the air.

Parameter

Air volume:30000m³/h

Application area  :300-250㎡/set

Power :3KW

Voltage:380V/220V/Customized

Frequency:50Hz/60Hz

Fan type: Axial Flow Fan

Water consumption:25-30Kg/h

Noise:80(dB)

Outlet dimension(L*W) :800*800mm

Dimension( L*W*H):1250*1250*1200mm

Other Specification Parameter

Model

Air volume(m³/h)

Power

(KW)

Voltage(V)

Outlet dimension

(mm)

Application area (㎡)

Dimension

( L*W*H)

(mm)

YNC-180

18000

1.1/1.5

380

670*670

80-120

1080*1080*950

YNC-220

22000

2.2

380

670*670

100-150

1180*1180*1160

YNC-300

30000

3.0

380

800*800

150-200

1300*1300*1180

Precautions for the installation of the air cooler

1. Installation environment

When installing the air cooler, it needs to be installed in a relatively nearby place with relatively fresh air, such as the outer wall and the roof. Of course, it is not advisable to install it near the toilet and the kitchen.

 

2. Installation method

The installation should be based on the location, select the appropriate size, determine the construction and installation of the pipeline, whether the link between the brackets is guaranteed, whether the pipeline will be blocked by obstacles, and whether the pipeline and hanger can be installed need to be considered.

 

3. Installation of exhaust port

The operation of the air cooler is to achieve the purpose of ventilation and cooling by inhaling the outdoor air, cooling the near-evaporative cooling pad and continuously conveying it to the room, and convecting the hot air and turbid air in the room to achieve ventilation and cooling. Therefore, the exhaust port needs to be equipped with a certain scale. Quantity, inlet and outlet ports should be kept in a ratio of 1:1. If there are many heating devices in the workshop and there is no exhaust port, enough exhaust ports should be opened at a height of more than 3 meters, or other equipment should be used to extract indoor hot air. , in order to achieve the ideal ventilation and cooling effect.

Installation Precautions: